Case Studies / Sellicks Green, Taunton
- Slate Roof
- Aiko Neostar N-Type
- 13.5kWh Storage
10.87kWp PV System, Taunton
A two-storey home at Sellicks Green using 10,000 kWh a year, matched almost exactly by an array on its slate roof. Storage took self-sufficiency from a third of that demand to nearly two thirds.
- 10.87kWparray on a slate roof
- 10,036kWh generated a year
- 63%of demand met on site

Specification
The System at a Glance
A high-usage household on a slate roof, wanting less grid reliance, storage in the loop and the wiring ready for an EV charge point later. The array was sized against the load profile rather than the roof area, which is the other way round from most of our solar panel installations.
Location
Sellicks Green, Taunton
Property
Two-storey residential home
System Size
10.87kWp
Roof
Natural slate, pitched
Panels
Aiko Neostar N-Type ABC, all black
Inverter
GivEnergy 12kW All in One hybrid
Storage
GivEnergy 13.5kWh lithium iron phosphate
Annual Use
10,000 kWh before the system went in
Generation
10,036 kWh projected each year
Status
Completed and commissioned
The survey establishes array size, orientation and storage before any quotation is prepared.
The Roof
A Slate Roof, and What It Asks For
Slate is unforgiving. It splits if it is walked on carelessly and it will not tolerate a fixing driven through the wrong place, so the mounting method matters as much as the panel specification. This roof took the array across one clear face, using hardware made for pitched slate. Our guide to how solar panels are installed covers the sequence in full.
The Fixing
Hooks into the rafters
Dedicated slate hooks anchor to the rafter rather than to the slate itself, so the load goes into the structure and the covering carries none of it.
The Covering
Slates sit flat again afterwards
The hook is shaped to let the slate above it lie down as it did before, which is what keeps the roof weathertight once the scaffold comes away.
The Layout
One clear face, filled
With a large uninterrupted pitch to work with, the array runs in continuous rows. Fewer breaks means fewer penetrations and a cleaner line from the ground.

Slate, tile, standing seam or flat, the survey establishes what your covering needs.
Hardware
High-Efficiency Cells and Storage With Headroom
A household drawing 10,000 kWh a year does not just need more panels, it needs a system that can deliver power quickly when several things are running at once. That points at the inverter as much as at the battery storage behind it.
Aiko Neostar N-Type ABC panels
All Back Contact cells, with every electrical path moved behind the cell. That takes the silver busbars off the face of the panel and leaves an even black surface, which matters on a slate roof where anything busy reads badly from the road.
- CellsAll Back Contact, N-Type
- EfficiencyUp to 23.8%
- FinishUniform black, no front busbars
GivEnergy 13.5kWh storage and 12kW All in One inverter
GivEnergy lithium iron phosphate cells, chosen for thermal stability and cycle life rather than for the last few percent of energy density. The All in One inverter handles generation, charging and grid interaction in a single unit.
- ChemistryLithium iron phosphate
- Capacity13.5kWh
- InverterGivEnergy 12kW All in One

Panel, inverter and battery are chosen against your roof and your consumption, not a package.
Outcome
What the System Delivers
The modelled electricity bill for this property falls from £2,635 a year to £573. The rest of the return comes from what the house sells back, plus a further £358 a year available on a time-of-use tariff by running the battery to a schedule rather than letting it charge whenever.
Financial performance
Year-one saving
The modelled drop in the annual electricity bill, from £2,635 down to £573.
Estimated payback
After which the system runs at a net gain, with the manufacturer warranties on panels and hardware still in force.
Environmental impact
CO2 avoided a year
Generation produced on the roof rather than drawn from centralised fossil-fuel plant.
avoided across 25 years
More than forty-six tonnes over the warranted life of the array, on the same annual figure.
grid independence
Up from 31% on generation alone. The battery is what closes the gap between the two.

Figures are modelled for this installation, using its array size, orientation and the household's own consumption pattern, and tariff rates move. Your property will produce its own set. For a house with a far smaller load, see our 8.46kWp Taunton case study, and for a coastal roof the 5.58kWp Watchet case study.
We model generation, saving and payback for your property before you commit to anything.
Takeaways
What This Project Shows
A large annual demand is a reason to design carefully, not a reason to settle for a dent in the bill. Three things carried this one, and more finished projects are shown in our solar panel installation gallery.
- Storage did more here than panels alone ever could Generation on its own covered 31% of what the house used. Adding 13.5kWh of storage took it to 63%, because the surplus now waits for the evening instead of leaving at the export rate and coming back at the import rate.
- Matching generation to consumption is a design decision 10,036 kWh generated against 10,000 kWh used is not a coincidence. The array was sized from the load profile, which is what makes the payback figure hold up.
- The mounting method is part of the specification On slate, the hooks and the way they meet the rafters decide whether the roof stays sound. That work is invisible once the panels are on, which is exactly why it is worth asking about.

Find out what your roof will carry and what it would generate, with no obligation.
Questions
Questions About This Installation
How much electricity does a 10.87kWp system generate in Taunton?
A 10.87kWp solar system on this Taunton roof is modelled to generate 10,036 kWh a year. As a rule of thumb, an unshaded array in this part of Somerset produces between 950 and 1,050 kWh annually for every kW installed, and where a particular system lands in that range depends on pitch, aspect and what stands in front of it. The figure here comes from system modelling against regional solar data rather than from a national average.
Why did a battery raise self-sufficiency from 31% to 63%?
The battery doubled self-sufficiency because generation and demand happen at different times of day. Without storage, a house can only use what it makes at the moment it makes it, and on a sunny afternoon that is a small fraction of the output. The rest leaves at the export rate and comes back in the evening at the much higher import rate. Storage keeps that surplus on site until the household wants it, which on this property took the share of generation used at home from 31% to 63%.
Is 13.5kWh of storage enough for a house using 10,000 kWh a year?
Yes, 13.5kWh is enough for this household, because storage is sized to the evening rather than to the annual total. A house of this size draws a few kWh through a typical evening and overnight, so 13.5kWh covers that and cycles fully on most days, which is what makes a battery pay. Going much larger would leave capacity unused for a good part of the year. Our guide to solar batteries sets out how the sizing is worked out at survey stage.
Can solar panels be fitted to a slate roof without damaging it?
Yes, solar panels can be fitted to a slate roof without damaging it, provided slate hooks are used and the roof is walked carefully. The hooks anchor into the rafters and are shaped so the slate above can lie flat again over the top, which keeps the covering weathertight. The risks come from careless access or from fixings driven straight through the slate, so ask any installer what mounting system they intend to use before you accept a quotation.
Why does the inverter's power rating matter as much as the battery size?
The inverter rating matters because capacity tells you how much energy the battery holds while the rating tells you how fast that energy can be delivered. If an oven, a kettle and a car charger are all running at once and the inverter cannot supply that in one go, the shortfall comes off the grid at full price no matter how much charge is sitting in the battery. The 12kW rating here gives the house room for those moments.
Call 0800 001 6258 or request a survey and we will answer it against your own property.
Next Step
Talk to Us About Your Roof
Sellicks Green shows what a high-usage household can do once generation and storage are sized against the way it actually lives. SolarGain designs solar and storage across Somerset and the South West, and the survey deals with what your property has rather than what an ideal one would look like.
It covers the roof and its covering, the shading across it, the supply and how the household uses electricity, all before a quotation is prepared. There is no charge and no obligation to proceed, and where it helps, the cost can be spread through solar finance.