Case Studies / Cutcombe, Somerset

  • Exmoor Ridge
  • Aiko Neostar 3S+ Bifacial
  • 80% Self-Supplied

7.95kWp PV System, Cutcombe

Fifteen bifacial panels on a single south-east slope nine miles south of Minehead, paired with a 5.76kWh battery and a hot water diverter. The household now takes four-fifths of its electricity from its own roof and sells most of the rest.

  • 7.95kWpfifteen-panel array
  • 6,548kWh generated a year
  • 80%of demand met on site
The completed all-black Aiko array on the pantile roof of a house at Cutcombe, Somerset

Specification

The System at a Glance

A house on the ridge between Exmoor and the Brendon Hills, with one usable roof slope, a modest annual demand and a strong appetite for using its own electricity rather than buying it. The specification follows from that: a generous array on the one slope available, storage sized to the household rather than to the array, and a diverter so surplus goes into hot water before it goes to the grid. The same approach sits behind every solar panel installation we carry out.

Location

Cutcombe, near Minehead, Somerset

Setting

High ground, ridge between Exmoor and the Brendon Hills

System Size

7.95kWp

Panels

15 x Aiko Neostar 3S+ 530W Dual Glass Bifacial

Roof

Pantile, south-east, 35 degree pitch

Inverter

FoxESS H1 G2 6.0kW single-phase hybrid, two MPPTs

Storage

FoxESS EP6 Plus 5.76kWh, heated cells

Hot Water

iBoost+ diverter with Buddy display

Protection

32A surge protection, DC and AC isolation

Generation

6,548 kWh projected each year

Status

Completed and commissioned

Get a Spec for Your Roof

The survey establishes array size, orientation, shading and storage before any quotation is prepared.

The Roof

One Slope, Two Different Shades

This roof gives one south-east face at a 35 degree pitch, turned fifty degrees east of due south, with two chimney stacks standing on it and higher ground closing the horizon to the west. Every one of those facts changes the design, and none of them stops the array from being worth fitting. Our guide to how solar panels are installed follows the sequence through.

The Aspect

South-east, and earlier in the day

Fifty degrees east of south means the roof takes the morning strongly and gives up the late afternoon. On a household that is up early and cooks in the evening off stored power, that is a better fit than the compass alone would suggest.

The Shading

Two chimneys and a western horizon

The survey measured a shade factor of 0.90 across one group of panels and 0.93 across the other. That difference is small on paper and decisive in the wiring, because a string performs to its weakest panel.

The Fixing

Pantile hooks, portrait and landscape

Forty-two Renusol RH1 pantile hooks anchor into the rafters beneath the covering, carrying twelve rails. Ten panels sit portrait on the lower course and five landscape above, which is how fifteen modules fit a slope this shape.

A SolarGain installer setting panels into the rails on the pantile roof at Cutcombe
Panels going into the rails on the south-east slope, portrait below and landscape above.
Ask About Your Roof

Chimneys, dormers, a shaded horizon: the survey measures what your own roof loses and what it keeps.

Hardware

A Large Array, a Small Battery and a Diverter

The array is deliberately bigger than the inverter and the battery is deliberately smaller than the array. Both decisions follow from a household that uses 2,800 kWh a year: there is roof to fill, but very little point paying for storage that would sit half empty. Surplus goes to the hot water cylinder first and to the grid after that. The current range is set out on our battery storage page.

15 x Aiko Neostar 3S+ 530W Dual Glass Bifacial

All Back Contact N-Type cells with glass on both faces. The contacts sit behind the cell rather than across the front, which frees light-collecting area and leaves the finished roof reading as one flat black plane rather than a grid of busbars.

Why bifacial here: the rear face picks up light reflected off the pantiles beneath the array. The gain on a close-mounted pitched roof is modest and it is not what justifies the panel. The glass-glass construction is, because it is stiffer than a back-sheet module and holds its output on a high, wet, wind-driven site.
  • CellsAll Back Contact, N-Type
  • Array15 modules, 7.95kWp total
  • Split8 on one tracker, 7 on the other

FoxESS H1 G2 6.0kW Hybrid and EP6 Plus 5.76kWh

A single-phase hybrid inverter with two independent MPPT inputs, paired with a 5.76kWh lithium iron phosphate battery that holds 5.2kWh usable. The house is supplied first, the battery takes what is left, the diverter takes the next slice into hot water, and only then does anything reach the network.

Why a heated battery: lithium cells charge poorly when cold, and a house on this ridge sits well above the coastal towns. The EP6 Plus warms its cells before charging, so winter mornings still put the surplus into storage rather than straight out to the grid.
  • Inverter6.0kW single-phase hybrid, two MPPTs
  • Storage5.76kWh, 5.2kWh usable
  • DiverteriBoost+ to the immersion, Buddy display
The FoxESS H1 G2 hybrid inverter and EP6 Plus battery installed at the Cutcombe property
The hybrid inverter and EP6 Plus battery, with isolation and surge protection alongside.
Talk Through the Options

Panel, inverter, battery and diverter are chosen against your roof and your consumption, not sold as a package.

Outcome

What the System Delivers

This system produces well over twice what the house consumes, so the return arrives in two very different halves: the electricity no longer bought, and the far larger volume sold back. Both are worth stating plainly, because a page that quotes only the self-supply figure hides where most of the value sits.

Generation and return

6,548

kWh generated a year

Modelled for this roof, its pitch, its aspect and its measured shading rather than taken from a national average.

£1,082

Year-one return

Made up of £572 in electricity no longer bought and £510 in Smart Export Guarantee payments on the surplus.

80%

of demand met on site

Four fifths of the year's electricity, split 36% straight from the panels and 44% out of the battery after dark.

Where the generation goes

4,139

kWh exported a year

Sixty-three per cent of everything the array makes leaves for the grid, which is what happens when a large roof meets a small demand.

548

kWh still imported

The whole of the household's remaining purchase from the network, concentrated in November, December and January.

69%

average battery use

The 5.76kWh pack cycles most of its capacity on a typical day, and passes 100% on shoulder-season days when it fills and empties twice.

Payback and carbon

8 yrs

Estimated payback

Reached in year nine on the modelled cash flow, after which the system runs at a net gain with the manufacturer warranties still in force.

1,311kg

CO2 avoided a year

Generation produced at the point of use rather than drawn from centralised fossil-fuel plant and pushed down the network.

33t

across 25 years

More than thirty-three tonnes over the warranted life of the array, on the same annual figure.

The view over open Somerset fields from the finished Aiko array at Cutcombe
The outlook from the finished array, with the open ground that gives this roof its clear southern sky.

Figures are modelled for this installation, using its array size, orientation, measured shading and the household's own consumption pattern. Your property will produce its own set. For a coastal roof nine miles north of here, see our 7.65kWp Minehead case study, and for another system that exports more than it keeps, the 8.46kWp Taunton case study.

See Your Own Numbers

We model generation, saving and payback for your property before you commit to anything.

Takeaways

What This Project Shows

A low-consumption house with one good slope, and three decisions that made the difference. More finished projects are shown in our solar panel installation gallery.

  • Size the battery to the house, not to the array. A 7.95kWp array alongside a 5.76kWh battery looks unbalanced until you see the 2,800 kWh of annual demand behind it. The pack still covers 44% of everything the household uses and cycles 69% of its capacity on an average day. A larger battery would have spent most of the year part full and added years to the payback.
  • Group panels by shading, not by row. The two chimneys and the western horizon do not shade this roof evenly, so the fifteen modules were split eight and seven across the inverter's two trackers, keeping the more affected panels together. Each group then performs to its own shade factor instead of one dragging the other down.
  • Give the surplus somewhere to go before the grid. With 63% of generation heading for export, a hot water diverter earns its place: it turns units worth a few pence on export into hot water the household would otherwise pay to heat. Storage, then hot water, then the network, in that order.

Thank you for the prompt service with the documents and thank Phil and the team for a very professional, efficient and tidy installation.

Homeowner, Cutcombe

The documents referred to are the handover pack: the electrical installation certificate, the commissioning record and the MCS certificate that an energy supplier asks for before accepting a Smart Export Guarantee application.

Book a Free Survey

Find out what your roof will carry and what it would generate, with no obligation.

Questions

Questions About This Installation

Why does this system export 63% of what it generates?

It exports 63% because the array makes 6,548 kWh a year and the household only uses 2,800 kWh, so most of the generation has nowhere else to go. The house takes 1,013 kWh straight from the panels, another 1,313 kWh arrives later out of the battery, and the remaining 4,139 kWh is sold to the grid under the Smart Export Guarantee. That is not a fault in the design. The roof had space, the panels are the cheapest part of the system per unit generated, and exported units still earn money, which is why the year-one return splits almost evenly between bills avoided and export payments. The scheme itself is set out by Ofgem.

Does a battery with a heating function make a difference on a high, cold site?

Yes, because lithium cells cannot accept a full charge below about five degrees, and without heating a battery simply refuses the surplus on the coldest mornings. The EP6 Plus warms its cells before charging, so a frosty January morning with sun on the roof still puts energy into storage rather than sending all of it to the grid at export rates. On a house standing on open high ground, where winter mornings run several degrees below the coastal towns nearby, that is the difference between a battery that works twelve months a year and one that half hibernates through the months when imported electricity costs the most.

Why were the fifteen panels split eight and seven rather than evenly?

They were split that way because the two groups take different amounts of shade, and the split follows the shading rather than the roof layout. The survey measured a shade factor of 0.90 across one group and 0.93 across the other, the difference coming from the two chimney stacks and the higher ground on the western horizon. A string of panels performs to its weakest module, so putting the more affected panels together on one MPPT input and the clearer ones on the other lets each group work to its own figure. Split evenly, the better panels would have been pulled down to the worse ones for no gain at all.

Is a hot water diverter worth fitting when the house already has a battery?

Yes on a system like this one, because the battery fills long before the generation stops. A 5.76kWh pack is full by late morning on a summer day here, and everything after that would otherwise leave at export rates of a few pence a unit. A diverter sends the next slice to the immersion heater instead, displacing whatever the household would have paid to heat the water with. The order matters: house first, battery second, hot water third, grid last. On a house exporting 4,139 kWh a year, the third step in that order is doing real work rather than duplicating the second.

Does a house that only uses 2,800 kWh a year get enough back from solar?

Yes, and this installation pays back in eight years on that consumption, because export income carries what self-supply cannot. A low-usage household saves less on its bills than a heavy one, and 2,800 kWh is well under half the demand of the other houses on this site. What changes the arithmetic is that the roof still had room for 7.95kWp, and every unit above the household's own needs earns an export payment instead. The result is a year-one return of just over a thousand pounds, of which roughly half never touches the house at all.

Ask Us Anything Else

Every roof raises its own questions. A survey is the quickest way to get yours answered.

Next Step

Talk to Us About Your Roof

SolarGain designs, installs and commissions solar and storage systems across Somerset and the wider South West, from the coast at Minehead to the villages on the Exmoor ridge. One family-run team handles the survey, the design, the connection application and the certification.

We submit the G98 or G99 application to the network operator on your behalf, register the installation under MCS and hand over the full documentation pack at commissioning. Domestic solar and battery storage currently carry 0% VAT, and payment can be spread through our solar finance options.