Case Studies / Taunton, Somerset

  • East and South Faces
  • AIKO Neostar 3S
  • EcoFlow Power Ocean

8.46kWp PV System, Taunton

Eighteen all-black panels split across two roof faces on a detached family home, generating close to three times what the household uses. The surplus goes out to the grid as income.

  • 8.46kWpeighteen-panel array
  • 7,177kWh generated a year
  • 85%of demand met on site
All-black solar panels being installed from scaffold on a detached home in Taunton, Somerset

Specification

The System at a Glance

A detached family home in Taunton with two usable roof faces and a modest annual demand. The array was sized to the roof rather than to the meter reading, which is what makes the numbers on this page unusual. The same approach runs through every solar panel installation we carry out.

Location

Taunton, Somerset

Property

Detached family home

System Size

8.46kWp

Orientation

East and south faces

Panels

18 x AIKO Neostar 3S 470W All Black

Inverter

EcoFlow Power Ocean 6kW hybrid, dual MPPT

Storage

EcoFlow Power Ocean 5.1kWh LFP

Annual Use

2,600 kWh before the system went in

Generation

7,177 kWh projected each year

Status

Completed and commissioned

Get a Spec for Your Roof

The survey establishes array size, orientation and storage before any quotation is prepared.

The Design

Two Roof Faces, One Array

Rather than filling the south slope and stopping, the array was spread across the east face as well. That widens the generating day at both ends instead of stacking everything into a few hours around noon, and it is the reason a house using 2,600 kWh a year still covers 85% of its own demand. Our guide to how solar panels are installed covers the mounting and wiring behind it.

Morning

The east face opens the day

East-facing panels are producing while the house is waking up, covering breakfast and starting the battery charging early rather than leaving it until the afternoon.

Late Morning to Afternoon

The south face carries the bulk

The southern array takes over as the sun comes round, and produces most of the 7,177 kWh. With the battery full by then, the balance goes out to the grid.

Through the Year

Winter is where size tells

A larger array on a low-demand house looks generous in June. In December, when output falls to a fraction of the summer figure, it is what keeps the house off the grid.

AIKO all-black panels laid across the tiled roof of the Taunton property
The array set out across the pitch, run right to the edge of the usable tile.
Ask About Your Roof

One face or three, the survey works out how much your own roof will carry.

Hardware

High-Efficiency Cells and a Backup-Ready Inverter

Two roof faces need an inverter that can manage them separately, and a house exporting most of what it makes needs one that handles the battery in the same box. The specification pairs N-Type panels with an inverter and battery storage from a single manufacturer.

AIKO Neostar 3S 470W, All Black

Eighteen modules using All Back Contact cells. Every electrical path sits behind the cell, so the silver busbars of a conventional panel are gone and the array reads as one continuous black surface.

Why it matters here: the array runs across two visible faces of a modern house, and N-Type cells hold their output better in the low light of a Somerset winter.
  • CellsAll Back Contact, N-Type
  • EfficiencyUp to 24.5%
  • FinishUniform black, no front busbars

EcoFlow Power Ocean 6kW hybrid and 5.1kWh LFP battery

Dual Maximum Power Point Tracking lets the east and south strings be managed apart, so neither face drags the other down. Lithium Iron Phosphate storage holds the daytime surplus for the evening, and the pack is modular if the household ever needs more.

Backup gateway: the inverter can be set up to keep selected circuits running during a power cut, which is worth having on a rural supply.
  • InverterPower Ocean 6kW hybrid
  • TrackingDual MPPT, one per roof face
  • StoragePower Ocean 5.1kWh LFP
The EcoFlow Power Ocean inverter and battery installed at the Taunton property
The EcoFlow Power Ocean unit, inverter and storage in one enclosure.
Talk Through the Options

Panel, inverter and battery are chosen against your roof and your consumption, not a package.

Outcome

What the System Delivers

This house makes far more than it uses, so the return splits two ways: the bills it no longer pays, and the electricity it sells back.

Financial performance

£1,124

Year-one return

Forecast from lower import bills alongside Smart Export Guarantee payments on a large surplus.

4,801

kWh exported a year

Sold back under an SEG tariff, which on this system is the larger half of the return.

8 yrs

Estimated payback

After which the system runs at a net gain, with the manufacturer warranties on panels and hardware still in force.

Environmental impact

1,453kg

CO2 avoided a year

Generation produced on the roof rather than drawn from centralised fossil-fuel plant.

5,191

car miles offset

The rough equivalent in emissions from an ordinary petrol car, every year the system runs.

67

mature trees

Matching the annual carbon absorption of around sixty-seven established trees.

Figures are modelled for this installation, using its array size, orientation and the household's own consumption pattern. Your property will produce its own set. For a smaller array on a single coastal slope, see our 5.58kWp Watchet case study, and for a split east-west roof the 7.81kWp Kilve case study.

See Your Own Numbers

We model generation, saving and payback for your property before you commit to anything.

Takeaways

What This Project Shows

An ordinary detached house, sized generously, ends up close to self-sufficient. Three things made that work, and more finished projects are shown in our solar panel installation gallery.

  • Filling the roof is worth more than matching the meter Sizing an array to last year's usage looks tidy on paper. Filling the usable roof gives you winter output when you need it and export income when you do not, and it costs less per panel to do it once.
  • Two faces beat one, even when one of them is south Adding the east slope stretched the generating day rather than raising the midday peak, which is what lifts the share of generation the household actually uses.
  • A modest battery still does the heavy lifting 5.1kWh is not a large pack, but on a house drawing 2,600 kWh a year it covers the evening comfortably. Grid dependence here sits at 15%.
The finished AIKO array running the length of the roof at the Taunton property
The finished array, panels running the full length of the pitch.
Book a Free Survey

Find out what your roof will carry and what it would generate, with no obligation.

Questions

Questions About This Installation

Why fit an 8.46kWp array on a house that uses only 2,600 kWh a year?

An 8.46kWp array suits this house because the usable roof sets what is worth installing, not last year's meter reading. Sizing an array to consumption leaves roof space empty and produces a system that struggles in winter, when output falls to a fraction of the summer figure. Filling the roof keeps the house largely self-supplied through the dark months and turns the summer surplus into export income rather than waste. It also costs less to scaffold and wire a roof once than to return and extend the array later.

What does a dual MPPT inverter do on an east and south roof?

A dual MPPT inverter tracks the two strings of panels separately, so the east face and the south face each run at the point where they produce most. On a single-tracker inverter the whole array is managed as one, so whichever face is producing less at that moment drags down the face producing more. With two trackers the slopes are handled apart, and each one works to its own conditions through the day.

How much is 4,801 kWh of exported electricity worth?

The value of 4,801 kWh of export depends entirely on the Smart Export Guarantee rate you are signed up to, and rates differ considerably between suppliers and change over time. On a system exporting this much, the gap between a poor rate and a good one adds up substantially across a year, so it is worth comparing suppliers rather than accepting whoever provides your import. Our Smart Export Guarantee guide sets out how the schemes work.

Do all-black panels generate as much as standard ones?

Yes, All Back Contact panels of this type generate as much as a conventional panel of the same size, and often more. The all-black finish is not a cosmetic film laid over an ordinary cell, it is a consequence of moving the electrical contacts to the rear. Taking the busbars off the front leaves more of the cell exposed to light, which is part of why these modules reach efficiency of up to 24.5%. Older all-black panels achieved the look by other means and did give something up for it, so the question is a fair one to ask of any panel you are offered.

Will the system keep working in a power cut?

The system keeps working in a power cut only if it has been wired and configured for backup, which this one has. A standard grid-tied system shuts down when the grid goes off, for the safety of anyone working on the network. The inverter here has a backup gateway, which isolates the house and runs selected circuits from the battery instead. That has to be specified at installation rather than added afterwards, so raise it at survey stage. Our guide to solar batteries covers what storage can and cannot do.

Ask Us Anything Else

Call 0800 001 6258 or request a survey and we will answer it against your own property.

Next Step

Talk to Us About Your Roof

Taunton shows what happens when a roof is filled rather than rationed. SolarGain designs solar and storage across Somerset and the South West, and the survey deals with what your property actually has rather than what an ideal one would look like.

It covers the roof faces, the shading across them, the supply and how the household uses electricity, all before a quotation is prepared. There is no charge and no obligation to proceed, and where it helps, the cost can be spread through solar finance.